-40%

CONTEC MS200 NIBP Simulator Non-Invasive Blood Pressure simulation Newest US

$ 369.07

Availability: 100 in stock
  • Restocking Fee: No
  • Country/Region of Manufacture: United States
  • Return shipping will be paid by: Buyer
  • MPN: 69450401
  • Model: MS200
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Condition: New
  • Item must be returned within: 60 Days
  • UPC: Does not apply
  • Bundle Listing: Yes
  • Brand: CON-TEC

    Description

    CONTEC MS200 NIBP Simulator Non-Invasive Blood Pressure simulation Newest US
    Product overview
    MS200 NIBP Simulator is a multi-purpose tester applied to the oscillometric Non-Invasive Blood Pressure (NIBP)Monitor. It can test the performance of multiform blood pressure monitor, provides dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing.
    Main features
    ◆ 4.3" LCD display,interface is concision,operation is simple and convenient.
    ◆ Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
    ◆ Build-in pump provides pressure source with leak and pressure relief tests
    ◆ NIBP simulations for both arm and wrist cuffs.
    ◆ Provides adult,neonate, seven variations patients conditions,user-defined simulations.
    ◆ Provides arrhythmias,respiratory artifact simulations.
    ◆ Built-in air chamber to simulate adult and neonate cuff.
    Main Parameters
    ◆ Heart Rate for NIBP Simulations
    Heart Rate Accuracy:   ±1BPM
    Patient Conditions:
    Weak pulse,Tachycardia,Obese ,Geriatric: ±1% ±1BPM
    Mild exercise:     ±1.5% ±1BPM
    Strenuous exercise:    ±3% ±1BPM
    ◆ Pressure measurement
    Units:      mmHg,kPa,cmH2O,inH2O,psi
    Range:      0 mmHg-400 mmHg
    Resolution: 1 mmHg,  0.1 kPa, 1 cmH2O,  1 inH2O,  0.1 psi
    Accuracy:   0 - 300 mmHg: ±0.5 % of reading ±1 mmHg           301 - 400 mmHg: ±2 % of reading
    ◆ Pressure Generation
    Pressure Generator, Static Pressure Range: 50 mmHg-400 mmHg
    Difference between target pressure and actual pressure : ±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
    Internal leak rate: <2 mmHg per minute, with a minimum volume of 300 cc
    ◆ Power
    100 - 240 V  AC 50/60 Hz, 60 VA
    ◆ Environmental Conditions
    Working temperature:  15℃ to 40℃(59℉ to 104℉)
    Storage temperature:  -20℃ to +65℃(-4℉ to +149℉)
    Relative humidity:    < 90%
    ◆ Display
    65k colors 4.3 inch TFT Display, brightness can be changed.
    ◆ Size (L x W x H)
    27 cm x 26.5 cm x 13.2 cm
    ◆ Weight
    3.5kg
    Accessories:
    Power cord
    Fuse
    User 's Manual
    Payment:
    *We accept payment from PAYPAL, Bank transfer,
    Visa,Credit Card and others.
    *All payments are expected within 7 days after the last
    winning auction is closed.
    Shippment
    *
    Clearance: we will ship your item(s) to your PayPal confirmed address.Please leave me your clear
    address,telephone,postal code.
    *
    All items will be dispatched within 2 bussiness day.
    *
    To US buyer,ship from USA warehouse by USPS 2-6 working days arrival.
    *
    To other country buyer,ship from China warehouse by Air mail 2-4 weeks arrival
    * The item will be declared as lower value for shipping only.We'd like to cooperate with you and declare the value of it
    as
    you want us to, so that it is more easier for you to clear the custom.
    Buy safe Products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for
    REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state
    and local regulatory agencies.If the item is subject to FDA regulation, We will verify your status as an
    authorized purchaser of this item before shipping of the item.
    If you have questions about legal obligations regarding sales of medical devices, you should consult with
    the FDA's Center for Devices and Radiological Health.
    The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with
    the code 197923,
    and certified by FDA of United States and CE,TUV of Europe.The  Fingertip Pulse
    Oximeter that is FDA 510K Approved
    About US
    Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in
    1992
    as a high-tech company.
    At present there are more than 1200 employees in our company.Our product line covers
    a
    wide range of 13
    categories.Most of the domestic hospitals are our
    customers.Contec hopes to cooperate with
    international companies to supply more innovative design and advanced
    technology products
    We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful
    business relationship with you.
    Powered by SoldEazy
    Only English user guide,if you need any other language,please contact us!
    Track Page Views With
    Auctiva's FREE Counter